Design Procedure for UASB Reactor

The UASB reactor can be designed as circular or rectangular. Modular design can be preferred when the volume of reactor exceeds about 400 m3. It is necessary to select proper range of operating parameters for design, such as OLR, SLR, superficial liquid upflow velocity (referred as liquid upflow velocity), and HRT.

Recommended loading range for design of UASB reactor based on COD concentration at average flow
Category of wastewaterCOD concentration (mg/L)OLR (Kg COD/m3.d)SLR (Kg COD/ kg VSS.d)HRT (Hours)Liquid Upflow Velocity (m/h)Expected Efficiency (%)
Low strengthUp to 7501.0 - 3.00.1 - 0.36 - 180.25 - 0.770 –75
Medium strength750 - 30002.0 - 5.00.2 - 0.56 - 240.25 - 0.780 - 90
High strength3000 - 10,0005.0 - 10.00.2 - 0.66 - 240.15 - 0.775 - 85
Very high strength> 10,0005.0 - 15.00.2 - 1.0 > 24---65 - 75

UASB Reactor Volume Calculation

Flow Rate :
COD concentration (mg/L) :
OLR (Kg COD/m3.d) :
Reactor Volume :

Formula:

Volume = (Flow Rate x COD concentration) / OLR

where,
  • COD - chemical oxygen demand
  • OLR - organic loading rates