Chemical Metering Pump Feed Rate Formula
Equation for calculate chemical metering pump feed rate is,
GPH = (GPM x .006 x PPM) / cc x SG
Where,GPM = flow to be treated.
.006 = Constant.
PPM = Dosage required.
cc = Concentration of chemical in pumped solution
SG = Specific gravity at pumped solution