Chemical Metering Pump Feed Rate Formula


Equation for calculate chemical metering pump feed rate is,

GPH = (GPM x .006 x PPM) / cc x SG

Where,
GPM = flow to be treated.
.006 = Constant.
PPM = Dosage required.
cc = Concentration of chemical in pumped solution
SG = Specific gravity at pumped solution