Dissipated Headloss Static Mixers Formula


Equation for calculate dissipated headloss static mixers is,

H = P / ( γ ×Q )

Where,
H = Static Mixer Design Dissipated Head Loss
P = Dissipated Power
γ = Specific Weight Water
Q = Flowrate